Cavity ring-down spectroscopy (CRDS) is a highly sensitive optical spectroscopic technique that enables measurement of absolute optical extinction by samples that scatter and absorb light. It has been widely used to study gaseous samples which absorb light at specific wavelengths, and in turn to determine mole fractions down to the parts per trillion level. The technique is also known as cavity ring-down laser absorption spectroscopy (CRLAS).
A typical CRDS setup consists of a laser that is used to illuminate a high-finesse optical cavity, which in its simplest form consists of two highly reflective mirrors. When the laser is in resonance with a cavity mode, intensity builds up in the cavity due to constructive interference. The laser is then turned off in order to allow the measurement of the exponentially decaying light intensity leaking from the cavity. During this decay, light is reflected back and forth thousands of times between the mirrors giving an effective path length for the extinction on the order of a few kilometers.
If a light-absorbing material is now placed in the cavity, the mean lifetime decreases as fewer bounces through the medium are required before the light is fully absorbed, or absorbed to some fraction of its initial intensity. A CRDS setup measures how long it takes for the light to decay to 1/e of its initial intensity, and this "ringdown time" can be used to calculate the concentration of the absorbing substance in the gas mixture in the cavity.
Detailed description
Cavity ring-down spectroscopy is a form of laser absorption spectroscopy. In CRDS, a laser pulse is trapped in a highly reflective (typically R > 99.9%) detection cavity. The intensity of the trapped pulse will decrease by a fixed percentage during each round trip within the cell due to absorption , scattering by the medium within the cell, and reflectivity losses. The intensity of light within the cavity is then determined as an exponential function of time.
\( I(t)=I_{0}\exp \left(-t/\tau \right) \)
The principle of operation is based on the measurement of a decay rate rather than an absolute absorbance. This is one reason for the increased sensitivity over traditional absorption spectroscopy, as the technique is then immune to shot-to-shot laser fluctuations. The decay constant, τ, which is the time taken for the intensity of light to fall to 1/e of the initial intensity, is called the ring-down time and is dependent on the loss mechanism(s) within the cavity. For an empty cavity, the decay constant is dependent on mirror loss and various optical phenomena like scattering and refraction:
τ\( \tau _{0}={\frac {n}{c}}\cdot {\frac {l}{1-R+X}} \)
where n is the index of refraction within the cavity, c is the speed of light in vacuum, l is the cavity length, R is the mirror reflectivity, and X takes into account other miscellaneous optical losses. This equation uses the approximation that ln(1+x) ≈ x for x close to zero, which is the case under cavity ring-down conditions. Often, the miscellaneous losses are factored into an effective mirror loss for simplicity. An absorbing species in the cavity will increase losses according to the Beer-Lambert law. Assuming the sample fills the entire cavity,
\( \tau ={\frac {n}{c}}\cdot {\frac {l}{1-R+X+\alpha l}} \)
where α is the absorption coefficient for a specific analyte concentration at the cavity's resonance wavelength. The decadic absorbance, A, due to the analyte can be determined from both ring-down times.
\( A={\frac {n}{c}}\cdot {\frac {l}{2.303}}\cdot \left({\frac {1}{\tau }}-{\frac {1}{\tau _{0}}}\right) \)
Alternatively, the molar absorptivity, ε, and analyte concentration, C, can be determined from the ratio of both ring-down times. If X can be neglected, one obtains
\( {\frac {\tau _{0}}{\tau }}=1+{\frac {\alpha l}{1-R}}=1+{\frac {2.303\epsilon lC}{(1-R)}} \)
When a ratio of species' concentrations is the analytical objective, as for example in carbon-13 to carbon-12 measurements in carbon dioxide, the ratio of ring-down times measured for the same sample at the relevant absorption frequencies can be used directly with extreme accuracy and precision.
Advantages of CRDS
There are two main advantages to CRDS over other absorption methods:
First, it is not affected by fluctuations in the laser intensity. In most absorption measurements, the light source must be assumed to remain steady between blank (no analyte), standard (known amount of analyte), and sample (unknown amount of analyte). Any drift (change in the light source) between measurements will introduce errors. In CRDS, the ringdown time does not depend on the intensity of the laser, so fluctuations of this type are not a problem. Independency from laser intensity makes CRDS needless to any calibration and comparison with standards.[1]
Second, it is very sensitive due to its long pathlength. In absorption measurements, the smallest amount that can be detected is proportional to the length that the light travels through a sample. Since the light reflects many times between the mirrors, it ends up traveling long distances. For example, a laser pulse making 500 round trips through a 1-meter cavity will effectively have traveled through 1 kilometer of sample.
Thus, the advantages include:
High sensitivity due to the multipass nature (i.e. long pathlength) of the detection cell.
Immunity to shot variations in laser intensity due to the measurement of a rate constant.
Wide range of use for a given set of mirrors; typically, ±5% of the center wavelength.
High throughput, individual ring down events occur on the millisecond time scale.
No need for a fluorophore, which makes it more attractive than laser-induced fluorescence (LIF) or resonance-enhanced multiphoton ionization (REMPI) for some (e.g. rapidly predissociating) systems.
Disadvantages of CRDS
Spectra cannot be acquired quickly due to the monochromatic laser source which is used. Having said this, some groups are now beginning to develop the use of broadband LED or supercontinuum sources[2][3][4] for CRDS, the light of which can then be dispersed by a grating onto a CCD, or Fourier transformed spectrometer (mainly in broadband analogues of CRDS). Perhaps more importantly, the development of ICOS based techniques have now been demonstrated over the range from the near UV to the mid-infrared. In addition, the frequency-agile rapid scanning (FARS) CRDS technique has been developed to overcome the mechanical or thermal frequency tuning which typically limits CRDS acquisition rates. The FARS method utilizes an electro-optic modulator to step a probe laser side band to successive cavity modes, eliminating tuning time between data points and allowing for acquisition rates about 2 orders of magnitude faster than traditional thermal tuning.[5]
Analytes are limited both by the availability of tunable laser light at the appropriate wavelength and also the availability of high reflectance mirrors at those wavelengths.
Expense: the requirement for laser systems and high reflectivity mirrors often makes CRDS orders of magnitude more expensive than some alternative spectroscopic techniques.
See also
Absorption spectroscopy
Laser absorption spectrometry
Noise-Immune Cavity-Enhanced Optical-Heterodyne Molecular Spectroscopy (NICE-OHMS)
Tunable Diode Laser Absorption Spectroscopy (TDLAS)
References
Soran Shadman; Charles Rose; Azer P. Yalin (2016). "Open-path cavity ring-down spectroscopy sensor for atmospheric ammonia". Applied Physics B. 122 (7): 194. Bibcode:2016ApPhB.122..194S. doi:10.1007/s00340-016-6461-5. S2CID 123834102.
K. Stelmaszczyk; et al. (2009). "Towards supercontinuum cavity ring-down spectroscopy". Applied Physics B. 94 (3): 369. Bibcode:2009ApPhB..94..369S. doi:10.1007/s00340-008-3320-z. S2CID 120500308.
K. Stelmaszczyk; et al. (2009). "Cavity ring-down absorption spectrography based on filament-generated supercontinuum light". Optics Express. 17 (5): 3673–8. Bibcode:2009OExpr..17.3673S. doi:10.1364/OE.17.003673. PMID 19259207. S2CID 21728338.
W. Nakaema; et al. (2011). "PCF-Based Cavity Enhanced Spectroscopic Sensors for Simultaneous Multicomponent Trace Gas Analysis". Sensors. 11 (2): 1620–1640. doi:10.3390/s110201620. PMC 3274003. PMID 22319372.
Truong, G.-W.; Douglass, K. O.; Maxwell, S. E.; Zee, R. D. van; Plusquellic, D. F.; Hodges, J. T.; Long, D. A. (2013). "Frequency-agile, rapid scanning spectroscopy". Nature Photonics. 7 (7): 532–534. Bibcode:2013NaPho...7..532T. doi:10.1038/nphoton.2013.98.
Anthony O'Keefe; David A.G. Deacon (1988). "Cavity ring-down Optical Spectrometer for absorption measurements using pulsed laser sources". Review of Scientific Instruments. 59 (12): 2544. Bibcode:1988RScI...59.2544O. doi:10.1063/1.1139895. S2CID 6033311.
Piotr Zalicki; Richard N. Zare (15 February 1995). "Cavity ring-down spectroscopy for quantitative absorption measurements". The Journal of Chemical Physics. 102 (7): 2708–2717. Bibcode:1995JChPh.102.2708Z. doi:10.1063/1.468647.
Giel Berden; Rudy Peeters; Gerard Meijer (2000). "Cavity ring-down spectroscopy: Experimental schemes and applications". International Reviews in Physical Chemistry. 19 (4): 565–607. Bibcode:2000IRPC...19..565B. doi:10.1080/014423500750040627. S2CID 98510055.
vte
FT-IR Raman Resonance Raman Rotational Rotational–vibrational Vibrational Vibrational circular dichroism
UV–Vis–NIR
Ultraviolet–visible Fluorescence Vibronic Near-infrared Resonance-enhanced multiphoton ionization (REMPI) Raman optical activity spectroscopy Raman spectroscopy Laser-induced
X-ray and
photoelectron
Energy-dispersive X-ray spectroscopy Photoelectron Atomic Emission X-ray photoelectron spectroscopy EXAFS
Nucleon
Radiowave
NMR Terahertz ESR/EPR Ferromagnetic resonance
Others
Acoustic resonance spectroscopy Auger spectroscopy Astronomical spectroscopy Cavity ring-down spectroscopy Circular dichroism spectroscopy Coherent anti-Stokes Raman spectroscopy Cold vapour atomic fluorescence spectroscopy Conversion electron Mössbauer spectroscopy Correlation spectroscopy Deep-level transient spectroscopy Dual-polarization interferometry Electron phenomenological spectroscopy EPR spectroscopy Force spectroscopy Fourier-transform spectroscopy Glow-discharge optical emission spectroscopy Hadron spectroscopy Hyperspectral imaging Inelastic electron tunneling spectroscopy Inelastic neutron scattering Laser-induced breakdown spectroscopy Mössbauer spectroscopy Neutron spin echo Photoacoustic spectroscopy Photoemission spectroscopy Photothermal spectroscopy Pump–probe spectroscopy Saturated spectroscopy Scanning tunneling spectroscopy Spectrophotometry Time-resolved spectroscopy Time-stretch Thermal infrared spectroscopy Video spectroscopy Vibrational spectroscopy of linear molecules
vte
List of laser articles List of laser types List of laser applications Laser acronyms
Laser types: Solid-state
Semiconductor Dye Gas
Chemical Excimer Ion Metal Vapor
Laser physics
Active laser medium Amplified spontaneous emission Continuous wave Doppler cooling Laser ablation Laser cooling Laser linewidth Lasing threshold Magneto-optical trap Optical tweezers Population inversion Resolved sideband cooling Ultrashort pulse
Laser optics
Beam expander Beam homogenizer B Integral Chirped pulse amplification Gain-switching Gaussian beam Injection seeder Laser beam profiler M squared Mode-locking Multiple-prism grating laser oscillator Multiphoton intrapulse interference phase scan Optical amplifier Optical cavity Optical isolator Output coupler Q-switching Regenerative amplification
Laser spectroscopy
Cavity ring-down spectroscopy Confocal laser scanning microscopy Laser-based angle-resolved photoemission spectroscopy Laser diffraction analysis Laser-induced breakdown spectroscopy Laser-induced fluorescence Noise-immune cavity-enhanced optical heterodyne molecular spectroscopy Raman spectroscopy Second-harmonic imaging microscopy Terahertz time-domain spectroscopy Tunable diode laser absorption spectroscopy Two-photon excitation microscopy Ultrafast laser spectroscopy
Laser ionization
Above-threshold ionization Atmospheric-pressure laser ionization Matrix-assisted laser desorption/ionization Resonance-enhanced multiphoton ionization Soft laser desorption Surface-assisted laser desorption/ionization Surface-enhanced laser desorption/ionization
Laser fabrication
Laser beam welding Laser bonding Laser converting Laser cutting Laser cutting bridge Laser drilling Laser engraving Laser-hybrid welding Laser peening Multiphoton lithography Pulsed laser deposition Selective laser melting Selective laser sintering
Laser medicine
Computed tomography laser mammography Laser capture microdissection Laser hair removal Laser lithotripsy Laser coagulation Laser surgery Laser thermal keratoplasty LASIK Low-level laser therapy Optical coherence tomography Photorefractive keratectomy Photorejuvenation
Laser fusion
Argus laser Cyclops laser GEKKO XII HiPER ISKRA lasers Janus laser Laboratory for Laser Energetics Laser integration line Laser Mégajoule Long path laser LULI2000 Mercury laser National Ignition Facility Nike laser Nova (laser) Novette laser Shiva laser Trident laser Vulcan laser
Civil applications
3D laser scanner CD DVD Blu-ray Laser lighting display Laser pointer Laser printer Laser tag
Military applications
Advanced Tactical Laser Boeing Laser Avenger Dazzler (weapon) Electrolaser Laser designator Laser guidance Laser-guided bomb Laser guns Laser rangefinder Laser warning receiver Laser weapon LLM01 Multiple Integrated Laser Engagement System Tactical High Energy Laser Tactical light ZEUS-HLONS (HMMWV Laser Ordnance Neutralization System)
Hellenica World - Scientific Library
Retrieved from "http://en.wikipedia.org/"
All text is available under the terms of the GNU Free Documentation License