Lower flammability limit (LFL),[1] usually expressed in volume per cent, is the lower end of the concentration range over which a flammable mixture of gas or vapour in air can be ignited at a given temperature and pressure. The flammability range is delineated by the upper and lower flammability limits. Outside this range of air/vapor mixtures, the mixture can not be ignited (unless the temperature and pressure are increased). The LFL decreases with increasing temperature; thus, a mixture that is below its LFL at a given temperature may be ignitable if heated sufficiently. For liquids, the LFL is typically close to the saturated vapor concentration at the flash point, however, due to differences in the liquid properties, the relationship of LFL to flash point (which is also dependent on the test apparatus) is not fixed and some spread in the data usually exists.

The \( {\displaystyle LFL_{mix}} \) of a mixture can be evaluated using the Le Chatelier mixing rule if the\( {\displaystyle LFL_{i}} \) of the components i are known:[2]

\( {\displaystyle LFL_{mix}={\frac {1}{\sum {\frac {x_{i}}{LFL_{i}}}}}} \)

Where \( {\displaystyle LFL_{mix}} \) is the lower flammability of the mixture, \( {\displaystyle LFL_{i}}\) is the lower flammability of the i-th component of the mixture, and \( x_{i} i\) s the molar fraction of the i i-th component of the mixture.
See also

Flash point
Minimum ignition energy
Stoichiometry

References

1. ASTM E681-04 http://www.astm.org/Standards/E681.htm
Le Chatelier, H. Notes sur le dosage du grisou par les limites d’inflammabilité. Ann. Mines 388–395 (1891).

Chemistry Encyclopedia

World

Index

Hellenica World - Scientific Library

Retrieved from "http://en.wikipedia.org/"
All text is available under the terms of the GNU Free Documentation License