A wire chamber or multi-wire proportional chamber is a type of proportional counter that detects charged particles and photons and can give positional information on their trajectory,[1] by tracking the trails of gaseous ionization.[2]

Description

Wire chamber schematic

Wire chamber with wires (W) and cathode (−) plates (P). The particles flying through T will ionize gas atoms and set free a charge that an amplifier (A) collects (impulse at the output).

The multi-wire chamber uses an array of wires at high voltage (anode), which run through a chamber with conductive walls held at ground potential (cathode). Alternatively, the wires may be at ground potential and the cathode held at a high negative voltage; the important thing is that a uniform electric field draws extra electrons or negative ions to the anode wires with little lateral motion.

The chamber is filled with carefully chosen gas, such as an argon/methane mix, such that any ionizing particle that passes through the tube will ionize surrounding gaseous atoms. The resulting ions and electrons are accelerated by the electric field across the chamber, causing a localised cascade of ionization known as a Townsend avalanche. This collects on the nearest wire and results in a charge proportional to the ionisation effect of the detected particle. By computing pulses from all the wires, the particle trajectory can be found.

Adaptations of this basic design are the thin gap, resistive plate and drift chambers. The drift chamber is also subdivided into ranges of specific use in the chamber designs known as time projection, microstrip gas, and those types of detectors that use silicon.[3][4]

Development

In 1968, Georges Charpak, while at the European Organization for Nuclear Research (CERN), invented and developed the multi-wire proportional chamber (MWPC). This invention resulted in him winning the Nobel Prize for Physics in 1992. The chamber was an advancement of the earlier bubble chamber rate of detection of only one or two particles every second to 1000 particle detections every second. The MWPC produced electronic signals from particle detection allowing scientists to examine data via computers.[5][6][7] The multi-wire chamber is a development of the spark chamber.[8]

Fill gases

In a typical experiment, the chamber contains a mixture of these gases:[2]

argon (about 2/3)
isobutane (just under 1/3)
freon (0.5%)

The chamber could also be filled with:

liquid xenon;[9]
liquid tetramethylsilane;[10] or
tetrakis(dimethylamino)ethylene (TMAE) vapour.[11]

MWPC electric field

Equipotential line and field line in a MWPC

Use

For high-energy physics experiments, it is used to observe a particle's path. For a long time, bubble chambers were used for this purpose, but with the improvement of electronics, it became desirable to have a detector with fast electronic read-out. (In bubble chambers, photographic exposures were made and the resulting printed photographs were then examined.) A wire chamber is a chamber with many parallel wires, arranged as a grid and put on high voltage, with the metal casing being on ground potential. As in the Geiger counter, a particle leaves a trace of ions and electrons, which drift toward the case or the nearest wire, respectively. By marking off the wires which had a pulse of current, one can see the particle's path.

The chamber has a very good relative time resolution, good positional accuracy, and a self-triggered operation (Ferbel 1977).[12]

The development of the chamber enabled scientists to study the trajectories of particles with much improved precision, and also for the first time observe and study the rarer interactions that occur through particle interaction.
Drift chambers

Chambre-a-derive-IMG 0524

Cut-away showing interior of a drift chamber
Drift chamber at the Musée des Arts et Métiers in Paris

If one also precisely measures the timing of the current pulses of the wires and takes into account that the ions need some time to drift to the nearest wire, one can infer the distance at which the particle passed the wire. This greatly increases the accuracy of the path reconstruction and is known as a drift chamber.

The drift chamber functions by balancing the loss of energy from particles caused by impacts with particles of gas, with the accretion of energy created with high-energy electrical fields in use to cause the particle acceleration.[13] Design is similar to the Mw chamber but instead with central layer wires at a greater distance apart.[8] The detection of charged particles within the chamber is possible by the ionizing of particles of gas due to the motion of the charged particle.[14]

The Fermilab detector CDF II contains a drift chamber called the Central Outer Tracker.[15] The chamber contains argon and ethane gas, and wires separated by 3.56 millimetres gaps.[16]

If two drift chambers are used with the wires of one orthogonal to the wires of the other, both orthogonal to the beam direction, a more precise detection of the position is obtained. If an additional simple detector (like the one used in a veto counter) is used to detect, with poor or null positional resolution, the particle at a fixed distance before or after the wires, a tri-dimensional reconstruction can be made and the speed of the particle deducted from the difference in time of the passage of the particle in the different part of the detector. This setup gives us a detector called a time projection chamber (TPC).

For measuring the velocity of the electrons in a gas (drift velocity) there are special drift chambers, velocity drift chambers which measure the drift time for known location of ionisation.
See also

Gaseous ionization detector
Micropattern gaseous detector
Particle detector

References

F. Sauli (1977), - Principles of operation of multiwire proportional and drift chambers Retrieved 2012-02-25
W.Frass. Physics - C4: Particle Physics Major Option - Particle Detectors. Oxford University. p. 11. Retrieved 2012-02-25. was located via Dr. C.N. Booth PHY304 Particle Physics Sheffield University
I. Kisel - [1] Retrieved 2012-02-28
University of Manchester - HEP - 101 Retrieved 2012-02-28
Computers in Physics, Sep/Oct 1992 - The Polish Language School for Foreign Students - Adam Mickiewicz University in Poznań - European Organization for Nuclear Research Archived 2012-02-14 at the Wayback Machine Retrieved 2012-02-25
H. Johnston - Physics world Retrieved 2012-02-25
"Milestones:CERN Experimental Instrumentation, 1968". IEEE Global History Network. IEEE. Retrieved 4 August 2011. - U.S. Department of Energy Research and Development Accomplishments Retrieved 2012-02-23
Physics. Guildford: University of Surrey. Retrieved 2012-02-28.
S.E.Derenzo - SLAC National Accelerator Laboratory, Stanford University ( U.S. Department of Energy Office of Science ); Muller, Richard; Derenzo, Stephen; Smadja, Gerard; Smith, Dennis; Smits, Robert; Zaklad, Haim; Alvarez, Luis (1971). "Liquid-Filled Proportional Counter". Physical Review Letters. 27 (8): 532–535. Bibcode:1971PhRvL..27..532M. doi:10.1103/PhysRevLett.27.532. OSTI 942298.
Degrange, B.; Guillon, J.; Moreau, F.; Nguyen-Khac, U.; De La Taille, C.; Tisserant, S.; Verderi, M. (1992). "Low energy calorimetry in a multiwire chamber filled with tetramethylsilane". Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 311 (3): 539. Bibcode:1992NIMPA.311..539D. doi:10.1016/0168-9002(92)90652-K.
Schotanus P; Van Eijk CWE; Hollander RW; CWE Van Eijk (1988). "Detection of LaF3:Nd3+ scintillation light in a photosensitive multiwire chamber". Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 272 (3): 913–916. Bibcode:1988NIMPA.272..913S. doi:10.1016/0168-9002(88)90780-2.; > G. Charpak Research on particle imaging detectors p.537 World Scientific, 1995 Retrieved 2012-02-28
T. Ferbel - (CERN report 1977)>
F. E. Close; M. Marten; C. Sutton (11 Nov 2004). The particle odyssey: a journey to the heart of the matter. Oxford University Press. Bibcode:2002pojh.book.....C. ISBN 978-0-19-860943-8. Retrieved 2012-02-12.
W. Blum; W. Riegler; L. Rolandi (4 Oct 2008). Particle detection with drift chambers. Springer. ISBN 9783540766841. Retrieved 2012-02-28.
Kotwal, Ashutosh V; Gerberich, Heather K; Hays, Christopher (2003). "Identification of cosmic rays using drift chamber hit timing". Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 506 (1–2): 110–118. Bibcode:2003NIMPA.506..110K. doi:10.1016/S0168-9002(03)01371-8.

Fermilab - glossary-photo- J. L. Lee Retrieved 2012-02-12

Physics Encyclopedia

World

Index

Hellenica World - Scientific Library

Retrieved from "http://en.wikipedia.org/"
All text is available under the terms of the GNU Free Documentation License